Nucleic Acid Extractor
Your Professional Nucleic Acid Extractor Supplier!
Kleibertus(Haikou) Electronic Technology GmbH is a foreign trade factory focusing on the life and health industry, committed to independent research and development, production and sales of high-quality products covering the entire medical and health industry chain. Our products cover areas such as medical diagnosis, in vitro diagnostic equipment, biosafety protection, disinfection and sterilization, purification engineering, cold chain transportation and medical beauty products, truly realizing a one-stop solution.
Why Choose Us
Full Industry Chain Coverage
Our products cover medical diagnosis, in vitro diagnostic equipment, biosafety protection, disinfection and sterilization, purification engineering, cold chain transportation and medical beauty products, truly realizing a one-stop solution.
Authoritative Certification Guarantee
The products have passed international certifications such as EU CE, EN, US NSF, FDA, etc., and the quality standards strictly meet the needs of the global market, winning high recognition from international customers.
Global Layout
Our business covers more than 190 countries and regions around the world. With an efficient international supply chain and customer service network, we ensure a quick response to global customer needs.
Leading in Technology and R&D
We always adhere to technology-driven, continue to increase R&D investment, ensure that our products always maintain high quality and high performance, and can meet the diversified needs of different markets.
Our Best-Selling Nucleic Acid Extractor
Our Company Has More Products to Offer, Please Browse the Product Categories on the Website, If You Have Any Needs, Please Contact Us.
High-throughput Nucleic Acid Detections
This fully automated High-throughput Nucleic Acid Detection system is expertly designed for large-scale laboratories, PCR tents, testing centers, disease control centers, and hospital labs, where high-volume sample processing is essential.
Automatic Nucleic Acid Extractor
The automatic nucleic acid extractor is a state-of-the-art, fully automated system designed to streamline laboratory operations by reducing user intervention and ensuring consistent, high-quality results. Featuring a user-friendly 7-inch touchscreen, the system offers fast response times and customizable lysis and elution temperatures, making it versatile for different reagent requirements. With an advanced UV disinfection function, users can set the disinfection time from 1 minute to 24 hours, ensuring a hygienic environment during sample processing.
Automatic Nucleic Acid Extraction Systems
This Automatic Nucleic Acid Extraction System is designed to provide highly efficient, automated nucleic acid extraction with minimal user intervention. It guarantees high-purity results by using optimized reagents, ensuring consistent and stable performance across multiple runs.

Nucleic Acid Extractor Technical Parameters
|
Throughput |
1-96 |
|
Speed |
Daily inspection volume ≥ 6000 tubes |
|
Adding Sample |
2-1000ul |
|
Temperature Accuracy |
±0.3℃ |
|
Temperature Uniformity |
±0.3℃ |
|
Module Temperature Range |
4-100℃ |
|
Sample Volume |
10-50ul |
|
Fluorescence Channel |
4 channels, FM , VIC , ROX , Cy5 |
|
Machine Function |
Putting the original tube on the machine + sample splitting + nucleic acid extraction + R C R system construction + amplification detection |
|
Sample Loading Method |
Flow loading, single sample volume 96 |
|
Consumables Added |
Flowing consumables, running without stopping |
|
Liquid Detection Scheme |
Pneumatic liquid level detection scheme, intelligent detection of blocked needle |
|
Sample Needle Specifications |
50μl, 200μl, 1000μl optional, disposable black conductive needle with filter |
|
Sampling Tube Adaptation |
Suitable for conventional 5mL, 10mL, 20/30mL virus sampling tubes |
|
Protective Function |
Power-on self-test, high temperature alarm, over-temperature protection, needle removal and needle removal protection |
|
Disinfection &Decontamination Methods |
UV lamp (cup compartment + extraction compartment + extraction area + sealing compartment + testing compartment), multi-directional disinfection |
|
Touch Screen |
Four 10.1-inch capacitive touch screens |
|
External Size |
6300*750*1900mm |
Automated & High Throughput
Full automation, up to 32 samples can be processed at one time, 4-5 times more efficient than manual method.
High Efficiency
Equipped with single sample reagent and consumable in case it is needed to prevent the waste of cost.
Standard
Multiple running programs can be edited as needed and a large storage core is provided to ensure the unity of experimental conditions.
Intelligent
Flexible throughput can meet different needs of extraction while unique UL design of control panel can display the operating parameters at one time, easy to understand and operate.
Precise Temperature
Fully contact between the deep well plates and heating modules, leads to a precise and stable temperature within each well, resulting in a high efficiency of sample lysis and nucleic acid elution..
Safe
Disposable tips and built-in UV radiation lower the safety risk of operation, and avoid the aerosol contamination between each run.
Nucleic Acid Extractor Principle
After the sample is lysed by the lysis buffer, the nucleic acid dissociated from the lysis/binding solution is specifically adsorbed by the magnetic beads. Through the cooperation of the magnetic rod and the magnetic tip comb, the magnetic attraction, transfer, release, mixing and other actions are completed to separate the magnetic beads adsorbing the nucleic acid from the lysis/binding solution. Various impurities that are not specifically bound to the magnetic beads are removed in the washing well, and finally the nucleic acid molecules are dissolved in the elution buffer.

Nucleic Acid Extractor Precautions
● The installation environment of the instrument: normal atmospheric pressure, temperature 20-35℃, typical use temperature 25℃, relative humidity 10%-80%, unobstructed air flow is 35℃ or below.
● Avoid placing the instrument near a heat source, such as an electric heater; at the same time, to prevent short circuits of electronic components, avoid splashing water or other liquids into it.
● The air inlet and exhaust vents are located on the back of the instrument, and at the same time, avoid dust or fibers from gathering at the air inlet to keep the air duct unobstructed.
● The nucleic acid extractor is at least 10cm away from other vertical surfaces.
● Instrument grounding: In order to avoid electric shock accidents, the input power cord of the instrument must be grounded.
● Keep away from live circuits: Operators are not allowed to disassemble the instrument without authorization. Replacement of components or internal adjustments must be completed by qualified professional maintenance personnel. Do not replace components when the power is turned on.
Packaging and Shipping
|
Packaging |
Foam, plastic bags, cartons |
|
Transportation methods |
Road transport, rail transport, sea transport, air transport |
Our Certificate





Video
FAQ
We're well-known as one of the leading nucleic acid extractor suppliers in China. Please feel free to buy high quality nucleic acid extractor in stock here from our factory. For customized service, contact us now.
Automatic Nucleic Acid Extraction Systems, Automatic Nucleic Acid Extractor, nucleic acid extractor