The MicroPette Mechanical Pipette is a precision instrument designed to meet the highest standards of accuracy and reliability. Rigorously tested according to ISO8655-2:2002, each pipette comes with a calibration certificate, confirming its precise weight-based calibration using 22°C distilled water. Its ergonomic design, featuring a lightweight build and low-force operation, ensures minimal user fatigue even during extended periods of use. The digital display provides easy visibility for accurate volume settings, with a wide range from 0.1μl to 10ml, making it suitable for diverse laboratory applications.
Built for durability, the MicroPette Mechanical Pipette can be safely autoclavable, allowing for easy sterilization between uses. This ensures optimal safety and cleanliness in the lab environment. Its construction with innovative materials not only guarantees long-lasting performance but also reduces the risk of repetitive strain injuries, offering both comfort and efficiency during high-frequency use.
For added versatility, the MicroPette Mechanical Pipette is available in 8-channel and 12-channel configurations, ideal for use with standard 96-well plates. The rotating dispensing head ensures easy and convenient pipetting, while the independent piston and tip cone assembly simplify maintenance. Furthermore, the composite material tip cone enables visual verification of the seal, adding an extra layer of reliability, and the pipette is compatible with universal tips for broader compatibility and convenience.
Technical Parameters
Models:
|
Single-channel Adjustable Volume Pipettes |
||||||
|
Volume Range |
Increment |
Test Volume (μl) |
Maximume Permissible Systematic error (Inaccuracy) |
Maximume Permissible Random error (Inaccuracy) |
||
|
% |
μl |
% |
μl |
|||
|
0.1-2.5μl |
0.05μl |
2.5 |
2.50% |
0.0625 |
2.00% |
0.05 |
|
1.25 |
3.00% |
0.0375 |
3.00% |
0.0375 |
||
|
0.25 |
12.00% |
0.03 |
6.00% |
0.015 |
||
|
0.5-10μl |
0.1μl |
10 |
1.00% |
0.1 |
0.80% |
0.08 |
|
5 |
1.50% |
0.075 |
1.50% |
0.075 |
||
|
1 |
2.50% |
0.025 |
1.50% |
0.015 |
||
|
2-20μl |
0.5μl |
20 |
0.90% |
0.18 |
0.40% |
0.08 |
|
10 |
1.20% |
0.12 |
1.00% |
0.1 |
||
|
2 |
3.00% |
0.06 |
2.00% |
0.04 |
||
|
5-50μl |
0.5μl |
50 |
0.60% |
0.3 |
0.30% |
0.15 |
|
25 |
0.90% |
0.225 |
0.60% |
0.15 |
||
|
5 |
2.00% |
0.1 |
2.00% |
0.1 |
||
|
10-100μl |
1μl |
100 |
0.80% |
0.8 |
0.15% |
0.15 |
|
50 |
1.00% |
0.5 |
0.40% |
0.2 |
||
|
10 |
3.00% |
0.3 |
1.50% |
0.15 |
||
|
20-200μl |
1μl |
200 |
0.60% |
1.2 |
0.15% |
0.3 |
|
100 |
0.80% |
0.8 |
0.30% |
0.3 |
||
|
20 |
3.00% |
0.6 |
1.00% |
0.2 |
||
|
50-200μl |
1μl |
200 |
0.60% |
1.2 |
0.15% |
0.3 |
|
100 |
0.80% |
0.8 |
0.30% |
0.3 |
||
|
50 |
1.00% |
0.5 |
0.40% |
0.2 |
||
|
100-1000μl |
5μl |
1000 |
0.60% |
6 |
0.20% |
2 |
|
500 |
0.70% |
3.5 |
0.25% |
1.25 |
||
|
100 |
2.00% |
2 |
0.70% |
0.7 |
||
|
200-1000μl |
5μl |
1000 |
0.60% |
6 |
0.20% |
2 |
|
500 |
0.70% |
3.5 |
0.25% |
1.25 |
||
|
200 |
0.90% |
1.8 |
0.30% |
0.6 |
||
|
1000-5000μl |
50μl |
5000 |
0.50% |
25 |
0.15% |
7.5 |
|
2500 |
0.60% |
15 |
0.30% |
7.5 |
||
|
1000 |
0.70% |
7 |
0.30% |
3 |
||
|
2-10ml |
0.1ml |
10ml |
0.60% |
60 |
0.20% |
20 |
|
5ml |
1.20% |
60 |
0.30% |
15 |
||
|
2ml |
3.00% |
60 |
0.60% |
12 |
||
|
8-channel Adjustable Volume Pipettes |
||||||||
|
Volume Range |
Increment |
Test Volume (μl) |
Maximume Permissible Systematic error (Inaccuracy) |
Maximume Permissible Random error (Inaccuracy) |
||||
|
% |
μl |
% |
μl |
|||||
|
0.5-10μl |
0.1μl |
10 |
1.50% |
0.15 |
1.50% |
0.15 |
||
|
5 |
2.50% |
0.125 |
2.50% |
0.125 |
||||
|
1 |
4.00% |
0.04 |
4.00% |
0.04 |
||||
|
5-50μl |
0.5μl |
50 |
1.00% |
0.5 |
0.50% |
0.25 |
||
|
25 |
1.50% |
0.375 |
1.00% |
0.25 |
||||
|
5 |
3.00% |
0.15 |
2.00% |
0.1 |
||||
|
50-300μl |
5μl |
300 |
0.70% |
2.1 |
0.25% |
0.75 |
||
|
150 |
1.00% |
1.5 |
0.50% |
0.75 |
||||
|
50 |
1.50% |
0.75 |
0.80% |
0.4 |
||||
|
12-channel Adjustable Volume Pipettes |
||||||||
|
Volume Range |
Increment |
Test Volume (μl) |
Maximume Permissible Systematic error (Inaccuracy) |
Maximume Permissible Random error (Inaccuracy) |
||||
|
% |
μl |
% |
μl |
|||||
|
0.5-10μl |
0.1μl |
10 |
1.50% |
0.15 |
1.50% |
0.15 |
||
|
5 |
2.50% |
0.125 |
2.50% |
0.125 |
||||
|
1 |
4.00% |
0.04 |
4.00% |
0.04 |
||||
|
5-50μl |
0.5μl |
50 |
1.00% |
0.5 |
0.50% |
0.25 |
||
|
25 |
1.50% |
0.375 |
1.00% |
0.25 |
||||
|
5 |
3.00% |
0.15 |
2.00% |
0.1 |
||||
|
50-300μl |
5μl |
300 |
0.70% |
2.1 |
0.25% |
0.75 |
||
|
150 |
1.00% |
1.5 |
0.50% |
0.75 |
||||
|
50 |
1.50% |
0.75 |
0.80% |
0.4 |
||||
|
Fixed Volume Pipettes |
||||||||
|
Volume Range |
Increment |
Test Volume (μl) |
Maximume Permissible Systematic error (Inaccuracy) |
Maximume Permissible Random error (Inaccuracy) |
||||
|
% |
μl |
% |
μl |
|||||
|
5μl |
- |
5μl |
1.3% |
0.065 |
1.2% |
0.06 |
||
|
10μl |
- |
10μl |
0.8% |
0.08 |
0.8% |
0.08 |
||
|
20μl |
- |
20μl |
0.6% |
0.12 |
0.5% |
0.1 |
||
|
25μl |
- |
25μl |
0.5% |
0.125 |
0.3% |
0.075 |
||
|
50μl |
- |
50μl |
0.5% |
0.25 |
0.3% |
0.15 |
||
|
100μl |
- |
100μl |
0.5% |
0.5 |
0.3% |
0.3 |
||
|
200μl |
- |
200μl |
0.4% |
0.8 |
0.2% |
0.4 |
||
|
250μl |
-- |
250μl |
0.4% |
1.0 |
0.2% |
0.5 |
||
|
500μl |
- |
500μl |
0.3% |
1.5 |
0.2% |
1.0 |
||
|
1000μl |
- |
1000μl |
0.3% |
3.0 |
0.2% |
2.0 |
||
|
2000μl |
- |
2000μl |
0.3% |
6.0 |
0.15% |
3.0 |
||
|
5000μl |
- |
5000μl |
0.3% |
15 |
0.15% |
7.5 |
||